The YAWEI S11-1600kVA oil immersed distribution transformer is designed for three-phase power distribution systems requiring voltage conversion from 10kV to 0.4kV. With a rated capacity of 1600kVA and a Dyn11 vector group, it is suitable for industrial facilities, commercial power distribution networks, and infrastructure projects.
This transformer features aluminum windings, No. 45 transformer oil as specified for the project, and an enhanced radiator arrangement designed to increase heat dissipation capacity. It is configured for an installation altitude of 2,150 meters, with a specified top-oil temperature rise limit of no more than 55K, subject to engineering verification for the actual operating conditions.
The project configuration includes a gas relay, pressure relief valve, terminal box, and an oil temperature indicator with a remote 4–20mA signal output using a two-wire connection. C3 corrosion protection, a camel-gray finish (YO1), red, yellow, and green bushing terminal protective covers on both the high- and low-voltage sides, and an 820mm track gauge are specified for this order.
Final drawings, nameplate details, and technical documents should be reviewed and approved before manufacturing.
| Availability: | |
|---|---|
| Quantity: | |
S11-1600
YAWEI
The YAWEI S11-1600kVA oil immersed distribution transformer is designed for three-phase power distribution systems requiring voltage conversion from 10kV to 0.4kV. With a rated capacity of 1600kVA and a Dyn11 vector group, it is suitable for industrial facilities, commercial power distribution networks, and infrastructure projects.
This transformer features aluminum windings, No. 45 transformer oil as specified for the project, and an enhanced radiator arrangement designed to increase heat dissipation capacity. It is configured for an installation altitude of 2,150 meters, with a specified top-oil temperature rise limit of no more than 55K, subject to engineering verification for the actual operating conditions.
The project configuration includes a gas relay, pressure relief valve, terminal box, and an oil temperature indicator with a remote 4–20mA signal output using a two-wire connection. C3 corrosion protection, a camel-gray finish (YO1), red, yellow, and green bushing terminal protective covers on both the high- and low-voltage sides, and an 820mm track gauge are specified for this order.
Final drawings, nameplate details, and technical documents should be reviewed and approved before manufacturing.
The S11-1600kVA transformer provides a rated capacity of 1600kVA, with a specified high-voltage rating of 10kV and low-voltage rating of 0.4kV. Its Dyn11 vector group consists of a delta-connected high-voltage winding and a star-connected low-voltage winding with a neutral terminal.
This configuration can support industrial and commercial distribution systems where the specified voltage ratings and vector group match the electrical system design.
The transformer is specified with aluminum windings on both the high- and low-voltage sides. Its radiator arrangement is designed with increased heat dissipation capacity to meet the project's thermal design requirements.
The specified top-oil temperature rise limit is ≤55K. Actual thermal performance must be verified against the approved design, ambient temperature, altitude, loading conditions, and applicable technical requirements.
The project includes an oil temperature indicator with a remote transmission signal output of 4–20mA using a two-wire connection. This signal can be integrated with a compatible monitoring or control system, subject to the receiving system's electrical and communication requirements.
The transformer also includes a gas relay, pressure relief valve, and terminal box as specified. These accessories support monitoring and protection functions, with their final ratings and arrangements confirmed in the approved technical documents.
The specified enclosure protection system is C3 corrosion protection, with a camel-gray finish identified as YO1. Red, yellow, and green protective covers are required for the high- and low-voltage bushings.
The project also specifies an 820mm track gauge and an installation altitude of 2,150 meters. These requirements should be reflected in the approved drawings and nameplate documentation where applicable.
>> Technical Parameters
| Type | Three Phase Oil-immersed Distribution Transformer |
| Model | S11-1600kVA |
| Installation | Outdoor |
| Altitude | ≤1000m |
| Rated Power | 1600KVA |
| Cooling Method | ONAN |
| Primary Voltage | 10KV |
| Secondary Voltage | 400V or others |
| Rated Frequence | 50/60HZ |
| Insulation oil | Mineral oil |
| Tapping Range | ±2×2.5%/±5% |
| Temperature rise℃) | 65 |
| Connection Group | Dyn11 |
| Total weight(kg) | - |
1. Industrial Power Distribution
The S20-200kVA transformer can supply low-voltage power to compatible industrial loads, workshops, and manufacturing facilities connected to a 10.5kV distribution system.
2. Commercial Buildings
Suitable for selected commercial properties, office buildings, and retail facilities requiring a dedicated medium-voltage to low-voltage transformer.
3. Distribution Network Upgrades
Can be considered for replacing existing distribution transformers or expanding local electrical capacity, provided the rated load and protection requirements are satisfied.
4. Infrastructure Projects
Applicable to selected public infrastructure and utility distribution projects requiring a 200kVA, 10.5kV/0.4kV transformer.
5. Facilities Requiring Corrosion Protection
The specified C3 coating system can be considered for environments within the applicable corrosion category. The suitability of the coating should be checked against the actual site conditions and project requirements.
Installation, Operation and Maintenance Guide
Transportation and Handling
Delivery Inspection
Storage Requirements
Installation Environment and Foundation
Electrical Connection and Grounding
Inspection of Bushings and Accessories
Pre-Energization Inspection
Insulation Resistance Testing
Winding Resistance Testing
Turns Ratio and Vector Group Verification
Transformer Oil Inspection
Protective Device Verification
Initial Energization
Operating Condition Monitoring
Routine Maintenance
Corrosion Coating Inspection
Troubleshooting and Fault Handling
Maintenance Records and Safety Procedures
All installation, testing, and maintenance work should be performed by qualified personnel in accordance with the manufacturer's instructions and applicable electrical safety regulations.