| Availability: | |
|---|---|
| Quantity: | |
ZS-2800-10/0.6/0.6
YAWEI
-
>> Product Introduction
The 2800kVA three‑phase oil‑immersed split‑winding transformer steps down 10kV primary to two independent 0.6kV secondary outputs. Its Dy11d0 vector group effectively suppresses triplen harmonics and suits multi‑pulse rectifiers, VFDs, and industrial drives. Housed in a hermetically sealed tank with mineral oil, it ensures robust cooling, moisture resistance, and long service life even in harsh environments like mines, petrochemical plants, and steel mills. Fully compliant with IEC 60076 and IEEE C57, it delivers stable, efficient, and safe power distribution for critical infrastructures.
Product Advantage
1. Precise Voltage Regulation & Dual‑Output Flexibility
Each secondary winding can be independently loaded up to 1400kVA with a tap changer (±2.5% regulation) under fluctuating grid conditions. This split design eliminates an extra transformer for separate low‑voltage networks, saving floor space and capital cost while providing load segregation and enhanced reliability.
2. Superior Harmonic Cancellation & Galvanic Isolation
The Dy11d0 connection reduces total harmonic distortion by up to 60% compared to conventional Yyn0 designs, protecting sensitive drives and PLCs from overheating and nuisance tripping. With 95kV impulse withstand capability, it offers complete galvanic isolation, shielding downstream equipment from surges and transient overvoltages.
3. Comprehensive Safety against Electrical Hazards
Independent secondary windings act as fault barriers—a short circuit on one side does not affect the other, ensuring continuous operation of critical loads. The oil‑immersed construction provides high dielectric strength and thermal inertia, minimising arc‑flash and insulation failure risks, while optional pressure relief and temperature monitors enhance personnel and asset protection.
4. Advanced Energy‑Loss Reduction
Using high‑permeability grain‑oriented steel and low‑loss windings, the transformer achieves no‑load losses ≤0.7% and load losses ≤1.1%, with a peak efficiency of 99.1%. Optimised flux design cuts transmission waste by over 38% versus traditional models, lowering operating costs and carbon footprint, and extending insulation life beyond 30 years.
>> Technical Parameters
| Type | Three‑phase oil‑immersed split‑winding distribution transformer |
| Model | ZS-2800-10/0.6/0.6 |
| Installation | Outdoor |
| Altitude | ≤1000m |
| Rated Power | 2800 kVA KVA or others |
| Cooling Method | ONAN |
| Primary Voltage | 10 kV |
| Secondary Voltage | 0.6 kV / 0.6 kV |
| Rated Frequence | 50/60HZ |
| Insulation oil | Mineral oil |
| Tapping Range | ±2×2.5%/±5% |
| Temperature rise℃) | 65 K |
| Connection Group | Dy11d0 |
| Total weight(kg) | ~ 8500 kg (depends on final design) |
>> Product Uses
1. Urban Power Distribution
Steps down 10kV to dual 0.6kV outputs for residential/commercial feeders; quiet operation (≤55dB) meets city noise limits.
2. Industrial Systems
Supplies two independent load groups simultaneously with 150% overload capacity – ideal for heavy machinery and peak production surges.
3. Renewable Energy
Used in solar/wind farms with anti‑corrosion protection; maintains 98% efficiency despite variable input, while Dy11d0 cuts harmonic distortion.
4. Rural Electrification
Low‑maintenance design works from ‑30°C to 50°C, with automatic voltage regulation (±3%) for weak or unstable grids.
5. Critical Infrastructure
Powers hospitals, data centres, and transport hubs; sealed tank prevents oil leaks and provides IP55 protection for uninterrupted service.
>> Product Operate Guide
Generic installation and use instructions for distribution transformer, containing the following sections:
1.Transportation
2. Deliverable check
3.Storage
4. Installation Enviornment Requirements
5.Electrical Installation
6.Common components
7.Common operation
8.Fuse installation
9.DC resistance
10. Pessure resistance
11. Transformer ration
12.Power-on opeartion
13.Power-off repair
14.General maintenance
15.Component maintenance
16.Component replacement
17.Transformer troubleshooting
18.Table of tightening torque
Product Video